Common reasons and solutions for errors in weighing modules

push time:2023-06-26 Popularity: source:1

  1、Weighing Module There are deviations during installation and use, equipment is not vertical, and pipelines are rigidly connected. Recheck if the installation is in place.

  

2. After calibration of the weighing module sensor, the shaking of the tank body during use may cause weighing deviation. At this time, it is necessary to recalibrate the zero point and range yourself, and the error after calibration is basically around 0.01 kilograms.

  

3. You can take a look at the angle difference of the electronic scale to see if it is a bit bad. If it is, adjust the angle difference and recalibrate it.

  

4. Hardware inspection for installation deviations, proper installation of soft connections, and presence of pipeline or tank stress that affects weighing accuracy.
 


 

  

5. Check if the connecting hose is under force, the installation and fixing bolts of the module are under force, and if there are any foreign objects in the gap between the anti overload bolts of the module and the weighing sensor. Also, check the accuracy of the instrument to see if the error is within the accuracy range.

  

6. The impact of pipeline connection and the ground support of the tank body, as well as the uncertain impact of the connected hoses on the system (especially if the hoses are not horizontally connected, the impact is greater), and the insufficient strength of the ground or support frame can have an impact.

  

7. The weighing module and junction box are greatly affected by air humidity, and factors such as temperature, vibration, and oscillation can also cause errors. If the junction box has water ingress, dry it with a hair dryer and perform calibration.

  

8. The impact of tank cooling water and room pressure difference, as well as changes in door opening and closing, as well as room pressure difference, can also have a certain impact on weighing. It is recommended to maintain the calibration state when using.