search
top search: ZXSCELLAmerican CeltronTedea, USAAmerican TranscellGerman HBMMettler Toledo
product core

    SBS ME weighing module for both dynamic and static use, available in the range of 500kg to 2T from the US Zhongkessel brand

    product details


    1、 Product Introduction of SBS ME Weighing Module from the US ZXSCELL Brand


    Product brand:ZXSCELL in the United States ZXSCELL

    Product series:SBS ME

    Product Type:Weighing Module

    Product Range: 500kg, 1T, 1.5T, 2T

    Product Introduction: The SBS ME weighing module is compatible with ZXSCELL's SLBC-ME series cantilever load cell, with a rated range of 500kg to 2T. The powerful functions of the weighing module enable it to easily meet the static and dynamic weighing needs in industrial production


    Product features:

    (1) Alloy steel material with nickel plating on the surface

    (2) Using SLBC-ME sensors

    (3) Adjustable installation height

    (4) Suitable for large static and small dynamic loads

    (5) Suitable for electronic platform scales, mixing plants, and ingredient scales, etc


    二、美国中克塞尔品牌 SBS ME称重模块图片


    三、SBS ME称重模块产品型号


    SBS ME 500kg

    SBS ME 1t

    SBS ME 1.5t

    SBS ME 2t


    四、称重模块现场安装注意事项


    Before installation, please check the foundation condition. Each installation point plane is perpendicular to the stress surface, and the levelness of the same foundation surface should be controlled within 1mm/m. The foundation bearing capacity should be greater than the range of the sensor

    1) Before installing the module, please adjust the sensor and upper board to a horizontal state;

    2) After the module installation is completed, please adjust the limit properly;

    3) The pendulum support is mainly used to prevent equipment from overturning and is not used for weighing and measuring. It has a certain gap with the bearing plate and the pendulum support nut is locked tightly;

    4) Cable color code (conventional sensor wire code, mainly based on certificate of conformity wire code)

    Note: During equipment debugging, if there is a large angle difference, poor instrument return to zero, or a small or no change in weight value after weight loading, please check if the module limit part is stuck or slightly affected by friction; Check the peripheral hardware connections of the device for external forces, such as the impact of dead connections in pipelines on weighing