1、 CD-GD-15T Load Cell Product Introduction
Product series:CD-GD
Product features:
-All stainless steel structure
-Fully welded seal
-Easy and fast installation
-High precision
-High stability
-Suitable for experimental machines, truck scales, and large hopper scales, etc
Optional range: 15T, 20T, 30T, 50T
Wiring method:
Red:+Motivation
Black: - Motivation
Green:+signal
White: - Signal
2、 Image of CD-GD Series weighing sensors in the United States
3、 CD-GD-15T Load Cell related models from the US
CD-GD-20t Load cell
CD-GD-30t Load cell
CD-GD-50t Load cell
4、 Product dimensions of the CD-GD-15T Load cell from the American Power Transmission
5、 Technical parameters of the CD-GD-15T Load cell of the American Power Transmission
Rated Output |
Rated output |
2.0mV/V ±0.1% |
Zero Balance |
Zero balance |
±1% of rated output |
Creep after 30 minutes |
creep |
±0.03% of rated output |
Nonlinearity |
Nonlinear |
±0.03% of rated output |
Hysteresis |
lagging |
±0.03% of rated output |
Repeatability |
Repeatability |
±0.03% of rated output |
Temp, effect on output |
Sensitivity temperature drift |
<0.002% of applied output/℃ |
Temp, effect on zero |
Zero temperature drift |
<0.002% of rated output/℃ |
Safe Temp. Range |
Available temperature range |
-10℃ to + 70℃ |
Temp. Compensated |
Temperature compensation range |
-10℃ to + 40℃ |
Safe Overload |
Safe load |
150% |
Input Impedance |
Input impedance |
1120 ohm ± 20 ohm |
Output Impedance |
Output impedance |
1000 ohm ± 5 ohm |
Insulation Resistance |
Insulation impedance |
>5000 M ohm (50V DC) |
Rated Excitation |
Recommended excitation voltage |
10V DC/AC |
Maximum Excitation |
Maximum excitation voltage |
15V DC/AC |
Cable Length |
Wire length |
13m |
Cable Color Code |
Wire color |
GN(+E) BK(-E) WT(+S) RD(-S)BN(+SEN) BU(-SEN) |
Guangzhou Zhongxin Automation Technology Co., Ltd. focuses on launching the following brand products to ensure that they are brand new and authentic, with excellent prices. Welcome new and old customers to inquire!
★ German HBM: Load cell - series such as Z6F, C16A, RTN, HLCB1, PW2D, PW6D, PW2C, PW6K, PW6C, PW10A, PW12C, PW16A, PW22, S40A, C2, etc
★ German HBM: Digital Sensors - C16I, FIT5AEB3, FIT7A
★ German HBM: Torque/force sensors - series T40B, T22, T5, U9C, C9C, S9M, U2B, S2M, etc
★ German HBM: weighing instruments/transmitters - WE2111, RM4220, BM40, AE101, AE301, EM201, and other series
★ American Celtron celtron: Sensors - STC, HBB, LPS, LOC, PSD, LCD, MBB, SQB, and other series
★ Tedea huntleigh: -- series 3410, 616, 355, 1015, 1040, 1022, 1260, 120, 1241, 240, etc
★ Transcell: Sensors - BSS, BSH, DBSL, SBST, CR, SBS, BAB, etc. series
★ Mettler Toledo: Load cell -- TSC, TSB, MTB, GD, SLB415, SLB215, MT1022, MT1260, MT1241, SB, SBS, SBH and other series
★ METTLER TOLEDO: Digital sensors - GDD, SLC7200760, PDX, SLC820, and other series
★ Mettler Toledo: control instruments -- IND331, IND245, IND320L, IND230, IND560, B520, IND110, WM0800, AJB and other series