122-100tLoad CellA product belonging to the Viday Tedea brand in the United States, with a standard stainless steel shell material, compact and economical column design, 6-wire (sensing) circuit, sealed to IP68, very suitable for multi unit applications, suitable for truck weighbridges, hoppers, and tank weighing.
. Introduction to American Tedea 122-100t Load Cell Products
Product Description:
-The Type 122 is a heavy-duty universal compression type weighing sensor, particularly suitable for hopper and tank weighing, as well as many other large-scale industrial applications, including weighbridges for truck weighing.
-The simple and compact column design and sturdy sealing structure of the Type 122 weighing sensor ensure its long-term service life in all types of on-site installations.
-The 122 type load cell is usually used for multi-sensor installation, so its standard output tolerance is within 0.1%.
-The other two induction lines provide feedback on the voltage reaching the weighing sensor. By inputting this voltage into an appropriate electronic device, it is possible to fully compensate for changes in lead resistance caused by temperature changes and/or cable extension.
Product Series: 122
Product features:
-Capacity 50-150 tons
-Very suitable for multi unit applications
-Compact and economical column design
-Sealed to IP68
-6-wire (sensing) circuit
-Standard stainless steel housing
-Optional range: 50t, 100t, 150t
. Actual photo of the 122-100t weighing sensor at Tedea in the United States
. Related models of 122-100t load cell from Tedea, USA
122-50T load cell
122-100T load cell
122-150T load cell
. Dimensions of American Tedea 122-100t weighing sensor products
. Technical parameters of American Tedea 122-100t weighing sensor
|
SPECIFICATIONS |
|
PARAMETER |
VALUE |
UNIT |
| Rated capacity - R.C. (Emax) |
50 |
100 |
150 |
t |
|
NTEP/OIML accuracy class |
Non Approved ¹ |
|
|
Maximum no. of intervals (n) |
2000 |
|
| Y=Em/Vmin |
2000 |
|
| Rated output - R.O |
1.5 |
2 |
mV/V |
|
Rated output tolerance |
0.0015 |
± mV/V |
|
Zero balance |
0.015 |
0.02 |
± mV/V |
|
Zero return, 30 min. |
0.030 |
±% of applied load |
|
Total error (per OIML R60) |
0.030 |
±% of rated output |
|
Temperature effect on zero |
0.03 |
±% of rated output/℃ |
|
Temperature effect on output, unbalanced |
zero point zero zero eight ² |
±% of load/℃ |
|
Temperature range, compensated |
5 to +45 |
℃ |
|
Temperature range, safe |
-20 to +60 |
℃ |
|
Maximum safe central overload |
150 |
% of R.C. |
|
Ultimate central overload |
200 |
% of R.C. |
|
Excitation, recommended |
10 |
VDC or VAC RMS |
|
Excitation, maximum |
15 |
VDC or VAC RMS |
|
Input impedance |
670 ± 15 |
1270 ± 20 |
1350 ± 30 |
Q |
|
Output impedance |
600 ± 5 |
1205 ± 5 |
1205 ± 5 |
Q |
|
Insulation resistance |
>2000 |
MO |
|
Cable length |
15 |
m |
|
Cable type |
6 wire, braided, PVC, single floating screen |
Standard |
|
Construction |
Stainless steel housing, plated alloy steel sensor |
|
|
Environmental protection |
IP68 |
|
(1) Typical 80% utilization
(2) Balanced span compensation is available upon request
All specifications subject to change without notice.
. Safety instructions for the 122-100t load cell of Tedea in the United States
1. The 122 series weighing sensors are designed for weighing applications and should not be considered compliant with relevant regulations for any other purpose.
2. To ensure safe operation, the load cell can only be used according to the instructions in the installation instructions. During use, it is also necessary to comply with the relevant legal and safety requirements of the application. This also applies to the use of attachments.
3. If the load cell is damaged, it may cause equipment damage or endanger personal safety. Therefore, users must take appropriate safety measures (such as safety devices to prevent falling, collapsing, or overloading). For safe and trouble-free operation, the weighing sensor must not only be transported, stored, positioned, and installed correctly, but also be carefully operated and maintained to avoid overload use.
4. The load of the 122-100t weighing sensor is 100T. When using it, attention should be paid to the possibility of instantaneous overload, which may also cause damage to the sensor. A larger range can be chosen.
Guangzhou Zhongxin Automation Technology Co., Ltd. focuses on launching the following brand products to ensure that they are brand new and authentic, with excellent prices. Welcome new and old customers to consult!
★ German HBM: Load cells - Z6F, C16A, RTN, HLCB1, PW2D, PW6D, PW2C, PW6K, PW6C, PW10A, PW12C, PW16A, PW22, S40A, C2 and other series
★ German HBM: Digital Sensors - C16I, FIT5AEB3, FIT7A
★ German HBM: Torque/force sensors - T40B, T22, T5, U9C, C9C, S9M, U2B, S2M and other series
★ German HBM: Weighing instruments/transmitters - WE2111, RM4220, BM40, AE101, AE301, EM201 and other series
★ American Celtron celtron: Sensors - STC, HBB, LPS, LOC, PSD, LCD, MBB, SQB, and other series
★ Tedea huntleigh: --341061635510151040102212601201241240 and other series
★ Transcell: Sensors - BSS, BSH, DBSL, SBST, CR, SBS, BAB and other series
★ Mettler Toledo: load cell -- TSC, TSB, MTB, GD, SLB415, SLB215, MT1022, MT1260, MT1241, SB, SBS, SBH and other series
★ METTLER TOLEDO: Digital sensors - GDD, SLC7200760, PDX, SLC820 and other series
★ Mettler Toledo: control instruments -- IND331, IND245, IND320L, IND230, IND560, B520, IND110, WM0800, AJB and other series