Guangzhou Zhongxin Automation Technology Co., Ltd】Professional supply of Japanese MINEBEA NS100A series
Load Cell, 【 NS100A sensor 】 NS100A-200kPa~NS100A-50Mpa_ The Japanese Minebea weighing sensor ensures fast delivery time, 100% genuine, and strives to become the top brand for sensor sales in China. Japanese Minebea BCL series load cell related models: CBE1-10kg, CBE1-20kg, CBE1-50kg, NS100A-100kgf, CBE1-200kg
 
The Japanese MINEBEA NS100A sensor is
One of our company's key competitive products, with absolute competitive prices, in stock, original, authentic, and reliable! Ensure satisfactory price and quality!We solemnly promise: "Within three months, if there are any quality issues, we will unconditionally return or exchange the goods, refund the full payment, and do not charge any fees. 1 year warranty, ready for repair!Introduction to the Japanese Minebea NS100A Series
Product brand:
Japan Minebea Load CellProduct abbreviation: Japan NS100A weighing sensor
Product model: NS100A
Product characteristics:
Bellows weighing sensorProduct principle: Resistance strain gauge
Optional range: 200kPa~50MPa
Application scope: electronic scales, commodity scales, platform scales, hopper scales
Appearance dimensions of the Japanese MINEBEA (CBE1) CBE1 series
  Japan NS100A-1MPPressure sensor specifications
Japan NS100A-1MPPressure sensor specifications
	
		
			| Rated range | 200 kPa~50 MPa | 
		
			| Safety overload | 200 %R.C. | 
		
			| Ultimate Overload | 300 %R.C. | 
		
			| accuracy | 0.2% R.O. (including nonlinearity, hysteresis, repeatability) | 
		
			| Rated output | Current: 4 mA~20 mA (2-wire, load resistance below 500 Ω, at 24 V) Voltage: 0 V~10 V (load resistance above 5 k Ω) | 
		
			| Response frequency | 1 kHz | 
		
			| Sensor supply voltage | DC 24 V (18 V to 28 V) | 
		
			| Consumption current | Approximately 20 mA | 
		
			| insulation resistance | Above 1000 M Ω (DC 50 V) | 
		
			| Compensation temperature range | -20 ℃~70 ℃ | 
		
			| Safe temperature range | -30 ℃~80 ℃ | 
		
			| The effect of temperature changes on zero point | 0.2 %R.O./10 ℃ | 
		
			| The impact of temperature changes on output | 0.2 %LOAD/10 ℃ | 
		
			| connector | With R03-RB5F (socket) | 
		
			| Protection level | IP44 (main body only) | 
		
			| Pressure inlet material | Stainless steel alloy | 
		
			| Cover material | Aluminum alloy (treated with aluminum oxide film) | 
		
			| Material of pressure part | Single crystal sapphire, etc | 
		
			| Installing screws | G3/8{PF} | 
		
			| weight | About 200 g (main body only) | 
		
			| Tightening torque | 20 N · m to 40 N · m | 
		
			| Special specifications | NS100A-A01: Accuracy 0.1% R.O. (rated range 200kPa~30MPa) NS100A-S70: IP67 waterproof, with zero adjustment function NS100A-CE: CE marked qualified product (only voltage output) | 
	
 
Complete model of the Japan MINIBEA (NS100A) NS100A series
NS100A-1MPPressure sensor model table: NS100A-200kpa, NS100A-500kpa, NS100A-1MPa, NS100A-2MPa, NS100A-5MPa, NS100A-10MPa, NS100A-20MPa, NS100A-25MPa,NS100A-30MPa,
NS100A-35MPa, NS100A-50MPa,
 
Extended Reading
Performance indicators of weighing sensorsThe performance of a weighing system can be measured by indicators such as linearity, hysteresis, repeatability, and creep.
Linear:Indicates the consistency between the actual output of the system and the theoretical straight line. As shown in the figure, when linear errors occur, the output of the system is correct at no load and full load, but the input-output points between these two points are inconsistent with the ideal state. Linear error is the maximum difference between the theoretical straight line and the actual output curve.
Lag:Indicates the degree to which the input-output curve of the system does not coincide during loading and unloading.
Repeatability:Indicates the degree of inconsistency in the system's output for several consecutive weighing of the same weight during the loading or unloading process. Usually expressed as the percentage of the total output that is the difference between the minimum output and the maximum output of the system under the same loading condition.
Creep:The characteristic of a system that bears a constant weight at a certain temperature, and the output changes over time due to the mechanical deformation of the elastic material of the sensor.
 
Pressure sensor
Common definitions of
Standard pressure: The amount of pressure expressed in atmospheric pressure. What is greater than atmospheric pressure is called positive pressure; Less than atmospheric pressure is called negative pressure.
Differential pressure (pressure difference): The relative difference between two pressures.
Absolute pressure (A): The amount of pressure expressed in absolute vacuum.
Relative pressure (gauge pressure) (G): Compared to standard pressure. Gauge pressure=absolute pressure - atmospheric pressure.
Atmospheric pressure: refers to the pressure generated by gravity on the air column on the Earth's surface. It is related to the altitude, latitude, and meteorological conditions at which it is located. 1 standard atmospheric pressure (1 atm) is equivalent to the pressure of a mercury column at a height of 760mm.
Vacuum: refers to a pressure state below atmospheric pressure. 1Torr=1/760 atmospheric pressure (atm).
Installation Guidelines for Pressure Sensors
 Before installation, please carefully read the product manual and verify the relevant information of the product.
The sensor should be installed in a ventilated, dry, corrosion-free, and cool place. If installed outdoors, a protective cover should be added to avoid the normal use of the product being affected by sunlight and rain.
Avoid strong impact or hitting during installation.
Connect the wires in the correct way and pay attention to protecting the outgoing wires of the sensor.
When cleaning the pressure interface and pilot hole of the sensor, trichloroethylene or alcohol should be injected into the pilot hole, gently shaken, and the liquid poured out multiple times.
It is prohibited to use any hard tool to penetrate the pressure hole to avoid damaging the sensitive core.
The above is [NS100A sensor] NS100A-200kPa~NS100A-50Mpa_ Detailed information of Japanese Minebea weighing sensors, if you are interested in [NS100A sensor] NS100A-200kPa~NS100A-50Mpa_ If you have any questions about the price, delivery time, model, and inventory of Minebea weighing sensors in Japan, please feel free to call