Guangzhou Zhongxin Automation Technology Co., Ltd】Professional supply of RDP_LDC sensors LDC500~LDC8000 electronic rulers_ UK RDP displacement sensor (LCD electronic ruler)_
UK RDP displacement sensor)Ensure fast delivery time, 100% original import, and strive to become the top brand of sensor sales in China. UK RDP_ LCD series displacement sensor related measurement length: 500mm, 1000mm, 2000mm, 3000mm, 4000mm, 6000mm, 8000mm
UK RDP_ Features of LCD series products
Brand: UK RDP
Name:
Displacement sensorModel: LCD
Travel: 500mm to 8000mm
UK RDP_ LCD series complete model
|
LCD |
LCD**C |
LCD**A |
|
LDC500,LDC1000,LDC2000,LDC3000,LDC4000,LDC6000,LDC8000 |
LDC500C,LDC1000C,LDC2000C,LDC3000C,LDC4000C,LDC6000C,LDC8000C,LDC10000C,LDC15000C,LDC18500C |
LDC500A,LDC1000A,LDC2000A,LDC3000A |
UK RDP_ LCD series parameter size
Expand reading
Mechanical installation
If necessary, shims can be used to adjust the force evenly on each sensor.
The top and bottom plates of the weighing module must be adjusted in a straight line to maintain the vertical direction of the force acting on the sensor.
When welding near the weighing module, be sure to pay attention to grounding, otherwise the welding current will pass through the sensor and cause damage.
The basic requirements are horizontal and have good rigidity, and there is a small difference in the required levelness between the foundations.
Be sure to tighten the support bolts of the weighing module during installation.
The weighing module must be installed in a convenient maintenance location.
Connection
All connections should use shielded insulated cables.
Electromagnetic interference can affect the output signal of sensors, causing weighing errors.
Isolate the power cord and sensor cable.
The junction box should be protected from moisture and corrosive substances.
Cables can be fitted with sleeves to prevent mechanical damage or erosion by damp or corrosive substances.
Do not arbitrarily change the length of the sensor cable, as this will change the output impedance of the sensor.
It is recommended to choose the recommended length and size of the connecting cable between the junction box and the weighing instrument, otherwise it may cause signal loss.
Preparation work before calibration
Install brackets on the tank body for hanging weights. The spacing between each bracket should be equal.
Before calibration, the output signal of each sensor should be tested to determine whether the force is evenly distributed to each sensor.
If necessary, the level of the module can be adjusted with a gasket or the potentiometer of the junction box can be adjusted to maintain consistent output for each sensor.
The above is the LDC500~LDC8000 electronic ruler for RDP_LDC sensors_ Detailed information on RDP displacement sensors in the UK, if you are interested in the LDC500~LDC8000 electronic ruler for RDP_LDC sensors_ If you have any questions about the price, delivery time, model, or inventory of RDP displacement sensors in the UK, please feel free to call us
18520271262 Chen GongObtain the RDP_LDC sensor LDC500~LDC8000 electronic ruler_ Latest price details for RDP displacement sensors in the UK.