1033Load CellA product belonging to the Viday Tedea brand in the United States, it is a lightweight single point weighing sensor with a single point of 400 × 400mm platform, aluminum structure, with a protection level of IP66, suitable for pricing scales, packaging scales, electronic scales, and platform scales.
. Introduction to Tedea 1033 Load Cell Products in the United States
Product Description:
-The 1033 model is a lightweight single point weighing sensor designed for direct installation of low-cost weighing platforms.
-This weighing sensor has small size, high accuracy, and low cost, making it very suitable for retail, platform scales, and counting scales.
-The moisture-proof protective coating ensures long-term stability throughout the entire compensation temperature range. The other two induction lines provide feedback on the voltage reaching the weighing sensor. By inputting this voltage into an appropriate electronic device, it is possible to fully compensate for changes in lead resistance caused by temperature changes and/or cable extension.
Product series: 1033
Product features:
-Capacity 10-30 kg
-Aluminum structure
-Single point 400 × 400mm platform
-Approved OIML R60
-IP66 protection level
-Can be used for metric and UNC threads-Optional:ATEX and IECEx certifications are available;The high stiffness version can be used for dynamic weighing applications
. Real photo of the 1033 weighing sensor at Tedea in the United States
. Tedea 1033 weighing sensor related models in the United States
1033-10kg load cell
1033-15kg load cell
1033-30kg load cell
. Dimensions of Tedea 1033 weighing sensor products in the United States
. Technical parameters of Tedea 1033 weighing sensor in the United States
PARAMETER | VALUE | UNIT |
Rated capacity - R.C. (Emax) | 10, 15, 30 | kg |
OIML accuracy class | Non-Approved | C3 ⑴ | C6 ⑵ | |
Maximum no. of intervals (n) | 1000 | 3000 | 6000 | |
Y = Ea/Vmm | 2000 | 10000 | 15000 | Maximum available |
Rated output - R.O | 2.0 | mV/V |
Rated output tolerance | 0.2 | ± mV/V |
Zero balance | 0.2 | ± mV/V |
Zero return, 30 min. | 0.0300 | 0.0170 | 0.0083 | ±% of applied load |
Total error | 0.0500 | 0.0200 | 0.0100 | ±% of rated output |
Temperature effect on zero | 0.0100 | 0.0023 | 0.0014 | ±% of rated output/℃ |
Temperature effect on output | 0.0030 | 0.0010 | 0.00058 | ±% of rated output/℃ |
Eccentric loading error | 0.0057 | 0.0057 | 0.0024 | ±% of rated load/cm |
Temperature range, compensated | -10 to +40 | ℃ |
Temperature range, safe | -20 to +70 | ℃ |
Maximum safe central overload | 150 | % of R.C. |
Ultimate central overload | 300 | % of R.C. |
Excitation, recommended | 10 | VDC or VAC RMS |
Excitation, maximum | 15 | VDC or VAC RMS |
Input impedance | 415 ± 15 | Q |
Output impedance | 350 ± 3 | Q |
Insulation resistance | >2000 | MQ |
Cable length | 0.5 | m |
Cable type | 4-wire, PVC, single floating screen | Standard |
Construction | Aluminum | |
Environmental protection | IP66 | |
Platform size (max.) | 400 x 400 | mm |
Recommended torque | 7.0 | N*m |
(1) 50% utilization
(2) 60% utilization
All specifications subject to change without notice.
. Safety instructions for Tedea 1033 load cell in the United States
1. The 1033 series weighing sensors are designed for weighing applications and should not be considered compliant with relevant regulations for any other purpose.
2. To ensure safe operation, the load cell can only be used according to the instructions in the installation instructions. During use, it is also necessary to comply with the relevant legal and safety requirements of the application. This also applies to the use of attachments.
3. If the load cell is damaged, it may cause equipment damage or endanger personal safety. Therefore, users must take appropriate safety measures (such as safety devices to prevent falling, collapsing, or overloading). For safe and trouble-free operation, the weighing sensor must not only be transported, stored, positioned, and installed correctly, but also be carefully operated and maintained to avoid overload use.
Guangzhou Zhongxin Automation Technology Co., Ltd. focuses on launching the following brand products to ensure that they are brand new and authentic, with excellent prices. Welcome new and old customers to consult!
★ ZXSCELL in the United States: Load cells - SLZX, SLBH, SLBC, SBSE, LZXD, LZX13, LZX10, DZXL, BHxA and other series
★ ZXSCELL in the United States: Weighing instruments - ZM02, ZXM-P1, ZXM06, DZM-X1, DZM-MINI, DZX7702X and other series
★ ZXSCELL in the United States: Weighing modules - SWB MK, UW MK, CW MK, SBT MK, SBS ME and other series
★ German HBM: Load cells - Z6F, C16A, RTN, HLCB1, PW2D, PW6D, PW2C, PW6K, PW6C, PW10A, PW12C, PW16A, PW22, S40A, C2 and other series
★ German HBM: Digital Sensors - C16I, FIT5AEB3, FIT7A
★ German HBM: Torque/force sensors - T40B, T22, T5, U9C, C9C, S9M, U2B, S2M and other series
★ German HBM: Weighing instruments/transmitters - WE2111, RM4220, BM40, AE101, AE301, EM201 and other series
★ American Celtron celtron: Sensors - STC, HBB, LPS, LOC, PSD, LCD, MBB, SQB, and other series
★ Tedea huntleigh: --341061635510151040102212601201241240 and other series
★ Transcell: Sensors - BSS, BSH, DBSL, SBST, CR, SBS, BAB and other series
★ Mettler Toledo: load cell -- TSC, TSB, MTB, GD, SLB415, SLB215, MT1022, MT1260, MT1241, SB, SBS, SBH and other series
★ METTLER TOLEDO: Digital sensors - GDD, SLC7200760, PDX, SLC820 and other series
★ Mettler Toledo: control instruments -- IND331, IND245, IND320L, IND230, IND560, B520, IND110, WM0800, AJB and other series