search
top search: ZXSCELLAmerican CeltronTedea, USAAmerican TranscellGerman HBMMettler Toledo
product core
    current location: home  > Product Center  > Load Cell

    【 U93 Force Sensor 】 U93/1KN~U93/50KN_ German HBM force sensor

    product details
                                                                                                                                                                          

    Guangzhou Zhongxin Automation Technology Co., Ltd】Professional supplyGerman HBM force sensor_ U93 series, 【 U93 force sensor 】 U93/1KN~U93/50KN_ German HBM force sensors guarantee fast delivery times, with 100% original imports, striving to become the top brand of sensor sales in China. German HBM force sensor_ U93 series related models: U93/1KN, U93/2KN, U93/5KN, U93/10KN, U93/20KN, U93/50KN.


     
    1-U93 Force Sensor Product Introduction

    Model: U93
    Brand:German HBM
    Name: Force Sensor
    Accuracy level: 0.02
    Range: 1KN, 2KN, 5KN, 10KN, 20KN, 50KN
    High precision and sturdy reliability
    Material: Stainless steel material, laser welded seal
    The temperature dependence of zero point is very low, and it is tightly sealed
    The influence of parasitic torque and force on measurement results is very small
    Usage: Plug and test, saving time, no need for on-site welding or assembly of plugs
    1-U93 is used for measuring tensile and compressive forces and is widely used in various static and dynamic measurement applications
     
    Appearance dimensions of 1-U93 force sensor



    The above is the German HBM brand_ U93 Force Sensor China General Agent 【 Zhongxin ★ Automation 】 solemnly promises
           Original and authentic products for sale, with good quality, low price, high-quality and professional communication, fast transportation, and the best service. Give you the best trading every day! Welcome to place an order. Attention: If you need a large quantity or cannot find the product you need in our store, please feel free to contact us at any time. We always provide you with the best quality and highly competitive prices. We solemnly promise to provide unconditional returns and exchanges within 3 months for any quality issues, at no cost, and with a one-year warranty.
     
    1-U93Technical parameters of force sensor



    1-U93 force sensor complete model:


    U93/1KN,U93/2KN,U93/5KN,U93/10KN,U93/20KN,U93/50KN
    1-U93/1KN,1-U93/2KN,1-U93/5KN,1-U93/10KN,1-U93/20KN,1-U93/50KN
     
    Expand reading
     
    1. From the measurement range
    When choosing a humidity sensor, the first step is to determine the measurement range. Except for meteorological and scientific research departments, temperature and humidity measurement and control generally do not require full humidity range (0-100% RH) measurement.
     
    2. Measurement accuracy should be precise
    Measurement accuracy is the most important indicator of humidity sensors. For humidity sensors, every one percentage point increase is a step up, or even a level up. Due to the need to achieve different accuracies, the manufacturing costs and selling prices vary greatly. So users must tailor their clothing according to their needs and should not blindly pursue "high, precision, and sharpness". If using a humidity sensor at different temperatures, the display value also needs to consider the influence of temperature drift. As is well known, relative humidity is a function of temperature, and temperature seriously affects the relative humidity in a specified space. Every 0.1 ℃ change in temperature. A humidity change (error) of 0.5% RH will be generated. If it is difficult to achieve constant temperature in usage scenarios, it is inappropriate to propose excessively high humidity measurement accuracy. In most cases, if there is no precise temperature control method, or if the measured space is unsealed, an accuracy of ± 5% RH is sufficient. For local spaces that require precise control of constant temperature and humidity, or for situations where humidity changes need to be tracked and recorded at any time, humidity sensors with an accuracy of ± 3% RH or higher should be selected. The requirement of accuracy higher than ± 2% RH may not even be achievable with a standard humidity generator for calibrating sensors, let alone the sensors themselves. It is still difficult to achieve an accuracy of 2% RH for relative humidity measuring instruments, even at 20-25 ℃. The characteristics given in the product documentation are usually measured at room temperature (20 ℃± 10 ℃) and in clean gas.
     
    3. Consider the issues of time drift and temperature drift
    In practical use, due to the influence of dust, oil stains, and harmful gases, electronic humidity sensors will age and have a decrease in accuracy over time. The annual drift of electronic humidity sensors is generally around ± 2%, or even higher. In general, manufacturers will indicate that the effective usage time for one calibration is 1 or 2 years, and recalibration is required upon expiration.
     
    The above is the U93 force sensor U93/1KN~U93/50KN_ Detailed information on German HBM force sensors, if you are interested in [U93 force sensors] U93/1KN~U93/50KN_ If you have any questions about the price, delivery time, model, or inventory of HBM force sensors in Germany, please feel free to call us18520271262 Chen GongObtain 【 U93 Force Sensor 】 U93/1KN~U93/50KN_ Latest price details for German HBM force sensors.
    product recommendation

    online service
    contact information

    Sales hotline:

    Miss Chen: 18520271262

      Miss Xie: 18688494254

    Mr. Huang: 18688492451

    Working hours:

    Monday to Saturday9:0018:00

    WeChat
    Scan and contact us
    Online Service